Fire doors only work when closed. Every fire-door must be fitted with a suitable self-closing device that brings the door back to its fully shut position in a controlled manner. Door closers for fire doors use a combination of hydraulics and springs to provide controllable force through the different stages of opening, closing, and latching. Read more about EN1154
BS EN 179 Emergency exit hardware such as manual push pads or levers to unlock a door, are covered by this standard. Whilst emergency exit doors don’t always need to be fire-rated, fire-resisting doors require such hardware when they are on an emergency escape route.
BS EN 1125 Panic exit devices. The difference between emergency exit hardware and panic exit hardware is that the latter is designed to be easier to activate in the event of diminished cognitive ability. An immediate threat in a crowded, unfamiliar venue is known to cause debilitating panic. Push-bar-to-open devices release upon general pressure, without requiring any dexterity.
BS EN 1155 electrically powered electrically powered devices for hold-open or swing-free doors. These are fitted to fire-resisting doors that are normally kept in the open position, and in the event of fire or power cut, allow the door’s self-closing device to function. Often used in high footfall and trolley or hospital bed access routes such as corridor fire doors in hospitals, shopping centres, and care-homes. Hold-open and free-swing door-closer devices are important to accessible design, in accordance with BS 8300-2.
BS 8300 Design of accessible and inclusive buildings. Many public buildings come under Approved Doc M where Fire doors should be easy to open and not put those less physically able at a disadvantage. Some high efficiencypower adjustable closersare tested to meet and assist BS8300, with easy opening and combined safe, controlled closure on a range of door sizes.
BS EN 1158 door coordinator devices. Where a double-leaf fire door is installed with rebated meeting stile, it is important that the two leaves shut in the correct order to establish the fire and smoke seal required. This function is usually achieved through a door coordinating device.
BS EN 12209 Mechanically operated locks and locking plates. Where fire-resisting doors require access control/security, the relationship between the door closer device and the lock’s latching mechanism is crucial. Compliance with BS 12209 of the lock indicates the suitability of the locking mechanism for use on fire resistance and/or smoke control doorsets.
BS EN 13637 Electrically controlled exit systems for use on escape routes. This standard covers fire door hardware that is designed to balance security (control of access) with a means of escape.
BS EN 13501-1 tests for how any construction material reacts to fire. EN13501 grades each material into Euroclass ratings. A1 is the highest rated as being non-combustible and non-contributing to the fire, with the lowest F grade being combustible and “easily flammable”.
BS EN 1303 This standard is about the grade of cylinder locks, in addition to security and durability. There are three grades of fire resistance identified by this standard. BS1303 will be of interest to manufacturers of fire and/or smoke control doorsets needing to find cylinder locks suitable for fire doors (that are not on an escape route).
BS EN 15684 A standard for the performance of mechatronic cylinder locks and electronic keys. Where these are to be used on fire-rated doorsets, they are given a grade depending on fire test performance.
BS 8214 Timber-based fire door assemblies covers the chain of supply, installation, and lifecycle of the majority of fire door grades. BS 8214 provides a code of practice for the specification, installation, and maintenance of timber fire doors up to 2 hours fire resistance (FD120). It takes a wide, holistic approach to the fire door as an enduring component of the building’s fire safety fabric. As many professional trades are involved in fire door safety, this standard covers all those not directly making the doorset; component suppliers, sub-contractors, architects, local authorities, plus other Responsible Persons and Duty Holders under the Fire Safety Order. As there is no published equivalent standard (at time of publication) for metal or composite material fire doors, BS 8214 is sometimes referred to informally within these sectors of the fire-door industry.
BS EN 15269 This standard is mainly of interest to fire testing houses. Its focus is on the extended application of test results when assessing assemblies without further testing.
BS EN 1906 Door Hardware and ironmongery such as handles. Only grade 1 fire-rated handles are suitable for use in fire door manufacture under BS 1906. This is indicated by the 4th digit on the door code plate.
ISO 3008-4 Fire resistance tests. Door and shutter assemblies – Linear joint fire seal materials used to seal the gap between a fire door frame and the supporting construction
BS EN 14846 This mainly deals with the security and durability of electromagnetically controlled locking mechanisms but does categorize the suitability or otherwise of use on fire-resisting doors.